SPHP Radiology Protocols

Radiology Protocols

Gallium Study

Gallium Study

1. Preparation
    a. No patient preparation

2. Isotope administration
    a. Patient will receive 8 mci Ga67 intravenously

3. Camera Parameters Planar imaging
    a. Whole Body Parameters
      i. MELP collimators
      ii. Matrix: 256 x1024
      iii. Zoom: 1.0
      iv. Detector: both
      v. Auto contour: On
      vi. Scan Speed: 8 cm/min
      vii. Patient position: supine
    b. Camera Parameters SPECT
      i. MELP collimators used for imaging
      ii. Matrix: 128X128
      iii. Zoom: 1
      iv. Time: 30 sec per stop
      v. Views: 64
      vi. Detector configuration 180
      vii. Orbit non circular
      viii. Mode step/shoot
      ix. Rotation: clockwise

4. Scanning protocol
    a. Patient will be injected with radiotracer intravenously
    b. Patient will wait 48 hours post injection for infection indication and 72 hours post injection for all other indications
    c. Immediately prior to placing patient on scanning table the patient should be asked to void.
    d. All metal objects should be removed from patient prior to scan start
    e. Patient will lay supine on the table with the head facing out.
    f. Patient will be scanned from the superior aspect of the skull to feet
    g. After wholebody scan, radiologist will decide how many bed SPECT/CT for the patient

5. SPECT/CT Reconstruction
    a. Nuclear Medicine Parameters
      i. Iterative OSEM 2D (4 subsets, 8 iterations)
      ii. Gaussian 6.0 filter
      iii. Chang's Attenuation Coefficient 0.15
    b. CT Parameters
      i. Abd Window
      ii. Body 5.0 B30s Med Smooth
      iii. 5 mm Slice

6. Post processing/Display/Achieve
    a. All acquired images will be adjusted for optimal viewing and appropriate labeling.
    b. All SPECT images will be displayed in coronal and sagittal planes with and without CT fusion and NM MIP
    c. Images will be sent to the PAC's system and Syngo Via for archiving/physician review

Scroll to Top