SPHP Radiology Protocols

Radiology Protocols

Gated chest C-

Gated CT Chest C- Aortic Aneurysm Protocol

(updated 6/12/2013, last reviewed 02/02/2026)

Assign to cardiac radiologist queue

Indication: Aortic size measurements for aneurysm follow up. Ordered by cardiac surgery and cardiology.


ECG gated


SERIES
  • 2 mm Axial  
  • 1 mm Axial lung windows 
  • 3 mm Coronal 
  • 3 mm Sagittal 
  • Coronal MIP lung
TECHNICAL PARAMETERS 
POSITIONING/MODE: supine / helical
kV/mA/rotation time: per scanner protocol, CareDose/iDose/ASIR, Care kV; <1 sec
PITCH: <1.5

SINGLE COLLIMATION WIDTH: 0.625 mm 

SLICE THICKNESS: 2 mm /1 mm 

KERNAL:  std soft tissue and lung

SFOV: large

COVERAGE:  thoracic inlet/apices -> posterior costophrenic sulci

ACQUISITION: craniocaudal

IV CONTRAST: no

RESPIRATION: Inspiration 

POSTPROCESSING:  3 mm coronal, 3 mm sagittal, coronal MIP lung